Moog IPRS01 Istruzioni per gli Interventi Pagina 6

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 24
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 5
Appendix A – Output Relay Conguration and Connections (cont.)
Active Solid-State
The third and least common method is the emitter follower where the camera output supplies the current used for detection. In this conguration is shown in
Figure 7.
Figure 7: Active Solid-State Relay I/O
Detect Connection
Output Relay Conguration and Connections
Output Relay Conguration
The relay output congurations vary based on the manufactures design. Because of these variations, the IP Reset I/O Detect input needs to operate in one of three
ways. Refer to your camera user manual for more information regarding the output relay conguration of your camera.
Passive Solid-State
The second method is similar, requiring the IP Reset to supply current to an open collector output transistor. This conguration is shown in Figure 6.
Figure 6: Passive Solid-State Relay I/O
Detect Connection
Figure 5: Dry Contact Relay I/O
Detect Connection
Dry Contact
The rst and most common method requires the IP Reset to supply current to the dry contacts of a relay. This conguration is shown in Figure 5.
I/O Detect Cable
Camera
Dry Contac t
BROW N
BLACK
I/O Detect Cable
Camera Open
Colle ctor Rel ay
BROW N
BLACK
I/O Detect Cable
Camera
Solid St ate
Sour cing Rel ay
BROW N
BLACK
+ Volts
Vedere la pagina 5
1 2 3 4 5 6 7 8 9 10 11 ... 23 24

Commenti su questo manuale

Nessun commento